Linux runtime: overrun detection for real-time timers and for plc execution.
If real-time timer wakes-up PLC thread too late (10% over period), then
warning is logged.
If PLC code (IO retreive, execution, IO publish) takes longer than requested
PLC execution cycle, then warning is logged, and CPU hoogging is mitigated
by delaying next PLC execution a few cylces more until having at least
1ms minimal idle time.
// widget_customhtml.ysl2
widget_desc("CustomHtml") {
longdesc
||
CustomHtml widget allows insertion of HTML code in a svg:foreignObject.
Widget content is replaced by foreignObject. HTML code is obtained from
"code" labeled text content. HTML insert position and size is given with
"container" labeled element.
||
shortdesc > Custom HTML insert
// TODO: support reload and POST based on variable content
}
widget_class("CustomHtml"){
||
frequency = 5;
widget_size = undefined;
dispatch(value) {
this.request_animate();
}
animate(){
}
init() {
this.widget_size = this.container_elt.getBBox();
this.element.innerHTML ='<foreignObject x="'+
this.widget_size.x+'" y="'+this.widget_size.y+
'" width="'+this.widget_size.width+'" height="'+this.widget_size.height+'"> '+
this.code_elt.textContent+
' </foreignObject>';
}
||
}
widget_defs("CustomHtml") {
labels("container code");
}